{"id":3249,"date":"2021-07-07T15:38:44","date_gmt":"2021-07-07T13:38:44","guid":{"rendered":"https:\/\/equipes.lps.u-psud.fr\/meso\/?page_id=3249"},"modified":"2021-08-30T10:24:47","modified_gmt":"2021-08-30T08:24:47","slug":"equipment","status":"publish","type":"page","link":"https:\/\/equipes.lps.u-psud.fr\/meso\/equipment\/","title":{"rendered":"Equipment"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\"><strong>Dry dilution refrigerator &#8211; Bluefors<\/strong><\/h4>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_143925-768x1024.jpg\" alt=\"\" class=\"wp-image-3420\" width=\"261\" height=\"348\" srcset=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_143925-768x1024.jpg 768w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_143925-225x300.jpg 225w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_143925-1152x1536.jpg 1152w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_143925-1536x2048.jpg 1536w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_143925-scaled.jpg 1920w\" sizes=\"auto, (max-width: 261px) 100vw, 261px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This fridge has a base temperature below 10mK and is equipped with a vector magnet (9T\/1T\/1T). The wiring allows DC and RF measurements.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"> <strong>Dry dilution refrigerator &#8211; Cryoconcept<\/strong> <\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"> This fridge has a base temperature of 10mK and is equipped with a 8T magnet. The wiring allows DC and RF measurements. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Several wet dilution fridges<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">We have 4 wet dilution fridges that  can be used with different magnets (1T, 12T, 8T\/0.7T vector magnet). Our experimental rooms are equipped for helium recovery. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Nanofabrication facility of the LPS<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">We have accessed to the nanofabrication facility of the LPS with resist spin coating, optical lithography, AFM measurement, &#8230; <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Scanning electron microscope &#8211; Zeiss Supra55VP<\/h4>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/th_supra55vp.jpg\" alt=\"\" class=\"wp-image-3400\" width=\"279\" height=\"279\" srcset=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/th_supra55vp.jpg 351w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/th_supra55vp-300x300.jpg 300w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/th_supra55vp-150x150.jpg 150w\" sizes=\"auto, (max-width: 279px) 100vw, 279px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">This SEM FEG is equipped with an e-beam lithography system (NPGS by Nabity) and EDS. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Helium focused ion beam &#8211; Zeiss Orion Nanofab<\/h4>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/Orion-NanoFab.jpg\" alt=\"\" class=\"wp-image-3403\" width=\"307\" height=\"279\" srcset=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/Orion-NanoFab.jpg 418w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/Orion-NanoFab-300x273.jpg 300w\" sizes=\"auto, (max-width: 307px) 100vw, 307px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">This focus ion beam used helium or neon. It can be used for high resolution observation, milling and also ion assisted deposition of different materials (tungsten or platinum).<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Metal deposition system &#8211; Plassys<\/h4>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145117-1024x768.jpg\" alt=\"\" class=\"wp-image-3421\" width=\"359\" height=\"270\" srcset=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145117-1024x768.jpg 1024w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145117-300x225.jpg 300w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145117-768x576.jpg 768w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145117-1536x1152.jpg 1536w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145117-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 359px) 100vw, 359px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">This metal deposition system has three chambers, devoted to different type of deposition. The first one is based on e-beam evaporation for metals like Al, Ti, Au, Pd, Nb, &#8230; The second chamber uses RF sputtering. The last chamber is a DC sputtering system for Nb, MoRe, &#8230;<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">DC sputtering system &#8211; Korvus<\/h4>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145218-1-768x1024.jpg\" alt=\"\" class=\"wp-image-3422\" width=\"234\" height=\"312\" srcset=\"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145218-1-768x1024.jpg 768w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145218-1-225x300.jpg 225w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145218-1-1152x1536.jpg 1152w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145218-1-1536x2048.jpg 1536w, https:\/\/equipes.lps.u-psud.fr\/meso\/wp-content\/uploads\/sites\/8\/2021\/08\/IMG_20210827_145218-1-scaled.jpg 1920w\" sizes=\"auto, (max-width: 234px) 100vw, 234px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">This DC sputtering system is specifically used to deposit Bi.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dry dilution refrigerator &#8211; Bluefors This fridge has a base temperature below 10mK and is equipped with a vector magnet (9T\/1T\/1T). The wiring allows DC and RF measurements. Dry dilution &#8230;<\/p>\n","protected":false},"author":18,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3249","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-json\/wp\/v2\/pages\/3249","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-json\/wp\/v2\/comments?post=3249"}],"version-history":[{"count":10,"href":"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-json\/wp\/v2\/pages\/3249\/revisions"}],"predecessor-version":[{"id":3425,"href":"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-json\/wp\/v2\/pages\/3249\/revisions\/3425"}],"wp:attachment":[{"href":"https:\/\/equipes.lps.u-psud.fr\/meso\/wp-json\/wp\/v2\/media?parent=3249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}