{"id":3217,"date":"2021-06-24T15:39:25","date_gmt":"2021-06-24T13:39:25","guid":{"rendered":"https:\/\/equipes.lps.u-psud.fr\/idmag\/?page_id=3217"},"modified":"2024-12-02T16:39:15","modified_gmt":"2024-12-02T15:39:15","slug":"magnetic-force-microscopy","status":"publish","type":"page","link":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/","title":{"rendered":"Magnetic force microscopy"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Two microscopes<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Park system NX10 with magnetic field (500 mT (in plane), 150 mT (out of plane)), in-situ transport stage to send current pulses (down to 1ns, 1A)<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Attocube LT-AFM, from 4 to 300 K, under development&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" data-id=\"3508\" src=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/LA-1056-1024x683.jpg\" alt=\"\" class=\"wp-image-3508\" srcset=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/LA-1056-1024x683.jpg 1024w, https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/LA-1056-300x200.jpg 300w, https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/LA-1056-768x512.jpg 768w, https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/LA-1056-1536x1024.jpg 1536w, https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/LA-1056-2048x1365.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" data-id=\"3452\" src=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/20241112_135112-768x1024.jpg\" alt=\"\" class=\"wp-image-3452\" srcset=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/20241112_135112-768x1024.jpg 768w, https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/20241112_135112-225x300.jpg 225w, https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/20241112_135112-1152x1536.jpg 1152w, https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/20241112_135112-1536x2048.jpg 1536w, https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2024\/11\/20241112_135112-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Two microscopes In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.<\/p>\n","protected":false},"author":4,"featured_media":3292,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"footnotes":""},"class_list":["post-3217","page","type-page","status-publish","has-post-thumbnail","hentry"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.3 - aioseo.com -->\n\t<meta name=\"description\" content=\"Two microscopes Park system NX10 with magnetic field (500 mT (in plane), 150 mT (out of plane)), in-situ transport stage to send current pulses (down to 1ns, 1A) Attocube LT-AFM, from 4 to 300 K, under development In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"IDMAG LPS - Imagerie et dynamique en magn\u00e9tisme \/ Imaging and Dynamics of Magnetism\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Magnetic force microscopy - IDMAG LPS\" \/>\n\t\t<meta property=\"og:description\" content=\"Two microscopes Park system NX10 with magnetic field (500 mT (in plane), 150 mT (out of plane)), in-situ transport stage to send current pulses (down to 1ns, 1A) Attocube LT-AFM, from 4 to 300 K, under development In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2021\/06\/LOGO_IDMAG.gif\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2021\/06\/LOGO_IDMAG.gif\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2021-06-24T13:39:25+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2024-12-02T15:39:15+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Magnetic force microscopy - IDMAG LPS\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Two microscopes Park system NX10 with magnetic field (500 mT (in plane), 150 mT (out of plane)), in-situ transport stage to send current pulses (down to 1ns, 1A) Attocube LT-AFM, from 4 to 300 K, under development In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2021\/06\/LOGO_IDMAG.gif\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/#listItem\",\"name\":\"Magnetic force microscopy\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/#listItem\",\"position\":2,\"name\":\"Magnetic force microscopy\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/#listItem\",\"name\":\"Home\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/#organization\",\"name\":\"IDMAG LPS\",\"description\":\"Imagerie et dynamique en magn\\u00e9tisme \\\/ Imaging and Dynamics of Magnetism\",\"url\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2021\\\/06\\\/LOGO_IDMAG.gif\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/#organizationLogo\",\"width\":635,\"height\":168},\"image\":{\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/#organizationLogo\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/#webpage\",\"url\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/\",\"name\":\"Magnetic force microscopy - IDMAG LPS\",\"description\":\"Two microscopes Park system NX10 with magnetic field (500 mT (in plane), 150 mT (out of plane)), in-situ transport stage to send current pulses (down to 1ns, 1A) Attocube LT-AFM, from 4 to 300 K, under development In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/#breadcrumblist\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2021\\\/06\\\/mfm-2-scaled.jpeg\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/#mainImage\",\"width\":1920,\"height\":2560,\"caption\":\"MFM during scan\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/magnetic-force-microscopy\\\/#mainImage\"},\"datePublished\":\"2021-06-24T15:39:25+02:00\",\"dateModified\":\"2024-12-02T16:39:15+01:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/#website\",\"url\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/\",\"name\":\"IDMAG LPS\",\"description\":\"Imagerie et dynamique en magn\\u00e9tisme \\\/ Imaging and Dynamics of Magnetism\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/equipes.lps.u-psud.fr\\\/idmag\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Magnetic force microscopy - IDMAG LPS","description":"Two microscopes Park system NX10 with magnetic field (500 mT (in plane), 150 mT (out of plane)), in-situ transport stage to send current pulses (down to 1ns, 1A) Attocube LT-AFM, from 4 to 300 K, under development In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.","canonical_url":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/#listItem","position":1,"name":"Home","item":"https:\/\/equipes.lps.u-psud.fr\/idmag\/","nextItem":{"@type":"ListItem","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/#listItem","name":"Magnetic force microscopy"}},{"@type":"ListItem","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/#listItem","position":2,"name":"Magnetic force microscopy","previousItem":{"@type":"ListItem","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/#listItem","name":"Home"}}]},{"@type":"Organization","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/#organization","name":"IDMAG LPS","description":"Imagerie et dynamique en magn\u00e9tisme \/ Imaging and Dynamics of Magnetism","url":"https:\/\/equipes.lps.u-psud.fr\/idmag\/","logo":{"@type":"ImageObject","url":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2021\/06\/LOGO_IDMAG.gif","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/#organizationLogo","width":635,"height":168},"image":{"@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/#organizationLogo"}},{"@type":"WebPage","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/#webpage","url":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/","name":"Magnetic force microscopy - IDMAG LPS","description":"Two microscopes Park system NX10 with magnetic field (500 mT (in plane), 150 mT (out of plane)), in-situ transport stage to send current pulses (down to 1ns, 1A) Attocube LT-AFM, from 4 to 300 K, under development In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/#website"},"breadcrumb":{"@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/#breadcrumblist"},"image":{"@type":"ImageObject","url":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2021\/06\/mfm-2-scaled.jpeg","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/#mainImage","width":1920,"height":2560,"caption":"MFM during scan"},"primaryImageOfPage":{"@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/#mainImage"},"datePublished":"2021-06-24T15:39:25+02:00","dateModified":"2024-12-02T16:39:15+01:00"},{"@type":"WebSite","@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/#website","url":"https:\/\/equipes.lps.u-psud.fr\/idmag\/","name":"IDMAG LPS","description":"Imagerie et dynamique en magn\u00e9tisme \/ Imaging and Dynamics of Magnetism","inLanguage":"en-US","publisher":{"@id":"https:\/\/equipes.lps.u-psud.fr\/idmag\/#organization"}}]},"og:locale":"en_US","og:site_name":"IDMAG LPS - Imagerie et dynamique en magn\u00e9tisme \/ Imaging and Dynamics of Magnetism","og:type":"article","og:title":"Magnetic force microscopy - IDMAG LPS","og:description":"Two microscopes Park system NX10 with magnetic field (500 mT (in plane), 150 mT (out of plane)), in-situ transport stage to send current pulses (down to 1ns, 1A) Attocube LT-AFM, from 4 to 300 K, under development In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.","og:url":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/","og:image":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2021\/06\/LOGO_IDMAG.gif","og:image:secure_url":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2021\/06\/LOGO_IDMAG.gif","article:published_time":"2021-06-24T13:39:25+00:00","article:modified_time":"2024-12-02T15:39:15+00:00","twitter:card":"summary","twitter:title":"Magnetic force microscopy - IDMAG LPS","twitter:description":"Two microscopes Park system NX10 with magnetic field (500 mT (in plane), 150 mT (out of plane)), in-situ transport stage to send current pulses (down to 1ns, 1A) Attocube LT-AFM, from 4 to 300 K, under development In house AFM tip functionnalisation for MFM usine sputtering (CoCr, Cr). Specific process for ultra low moment tips.","twitter:image":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-content\/uploads\/sites\/5\/2021\/06\/LOGO_IDMAG.gif"},"aioseo_meta_data":{"post_id":"3217","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":null,"created":"2022-01-10 16:07:53","updated":"2026-09-21 10:00:38","seo_analyzer_scan_date":null,"focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/equipes.lps.u-psud.fr\/idmag\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tMagnetic force microscopy\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/equipes.lps.u-psud.fr\/idmag\/"},{"label":"Magnetic force microscopy","link":"https:\/\/equipes.lps.u-psud.fr\/idmag\/magnetic-force-microscopy\/"}],"_links":{"self":[{"href":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-json\/wp\/v2\/pages\/3217","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-json\/wp\/v2\/comments?post=3217"}],"version-history":[{"count":4,"href":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-json\/wp\/v2\/pages\/3217\/revisions"}],"predecessor-version":[{"id":3542,"href":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-json\/wp\/v2\/pages\/3217\/revisions\/3542"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-json\/wp\/v2\/media\/3292"}],"wp:attachment":[{"href":"https:\/\/equipes.lps.u-psud.fr\/idmag\/wp-json\/wp\/v2\/media?parent=3217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}